Page 229 - index
P. 229
Ball Valves
Electrically Actuated 3-Way Stainless Ball Valves - 'T / L' Port
Features:
3-Way Stainless Ball Valve
• full port
• female NPT ends
• blow-out proof stem
• live-loaded stem packing
• ISO 5211 mounting pad See page 210 for fow path options.
• 100% air tested under water at 80 PSI
• working pressure: ¼" to 1": 1000 PSI; Customer verifcation is critical. If fow path
1¼" to 2": 800 PSI needs to be changed after being shipped,
• temperature range: -20°F to 300°F labor and shipping charges will apply.
Electric Actuator
• lightweight powder coated aluminum alloy For spring return actuators: must note fail
housing
• NEMA 4/4X waterproof and dustproof position.
• extended duty cycle induction motor
• high alloy steel gear train
• H-insulation class
• visual position indication
• space heater is standard
• manual override standard: ½" - 1½"
• working temperature: -41°F to 140°F
• ISO 9001, CS, CE and CSA-C US Certifed
• RoHS compliant
E ØB
ØB
A
A
C D C
¼" - 1¼" 1½" - 2"
Dimensions are approximate. Engineering dimensions are available upon request. * T = t style
Specifcations are subject to change without notice. * L = l style
316 Stainless Steel
Size A B C D E Override
Part #
¼" 9.01 6.06 2.83 1.41 N/A standard BV3IG*F-0251
⅜" 9.01 6.06 2.83 1.41 N/A standard BV3IG*F-0381
½" 9.21 6.06 3.26 1.63 N/A standard BV3IG*F-0501
¾" 9.21 6.06 3.89 1.94 N/A standard BV3IG*F-0751
1" 9.74 6.06 4.40 2.20 N/A standard BV3IG*F-1001
1¼" 10.04 6.06 4.92 2.46 N/A standard BV3IG*F-1251
1½" 12.92 7.87 5.86 2.93 12.99 handwheel BV3IG*F-1501
2" 13.67 7.87 6.85 3.42 12.99 handwheel BV3IG*F-2001 V
A wide variety of options are available: modulating, extra switches, transmitters, potentiometer, etc.
Contact Dixon Sanitary at 800.789.1718 or visit dixonvalve.com for details.
Caution !
Even though there are torque safety factors built into our automated ball valve packages, actual service conditions
must also be considered when selecting the proper product for the appropriate application.
For example: Severe service conditions such as dirty water, dirty air, all slurries, raw sewage water, oils, and other
viscous fuids can have a dramatic affect in raising the torque requirements of ball valves as much as 75% and therefore larger actuators
may be required. Please consult the factory when dealing with these types of applications.
Dixon Sanitary 2014 800.789.1718 227