Electrically Actuated 3-Way Brass Ball Valves - 'T / L' Port

Features:
3-Way Brass Ball Valve
• reduced port
• blow-out proof stem
• chrome-plated brass ball
• PTFE seats with O-ring backing for low
operating torque
• ISO 5211 mounting pad
• 100% tested See page 210 for fow path options.
• pressure rating: 400 PSI WOG 100 PSI WSP
• maximum temperature: 300ºF
Customer verifcation is critical. If fow
Electric Actuator path needs to be changed after being
• lightweight powder coated aluminum alloy shipped, labor and shipping charges will
housing apply.
• NEMA 4/4X waterproof and dustproof
• extended duty cycle induction motor For spring return actuators: must note fail
• high alloy steel gear train position.
• H-insulation class
• visual position indication
• space heater is standard
• manual override standard: ½" - 1½"
• working temperature: -41°F to 140°F
• ISO 9001, CS, CE and CSA-C US Certifed
• RoHS compliant

ØB

ØB



A
A






C D C D
¼" - 1¼" 1½" - 3"
Dimensions are approximate. Engineering dimensions are available upon request. * T = t-style
Specifcations are subject to change without notice. * L = l-style


Size A B C D Override Brass Part #

¼" 8.76 6.06 2.64 1.32 standard BV3BV*R-0251
⅜" 8.76 6.06 2.64 1.32 standard BV3BV*R-0381
½" 8.76 6.06 2.87 1.44 standard BV3BV*R-0501
¾" 8.85 6.06 3.19 1.60 standard BV3BV*R-0751
1" 9.19 6.06 3.74 1.87 standard BV3BV*R-1001
1¼" 9.41 6.06 4.39 2.20 standard BV3BV*R-1251
1½" 9.90 6.06 4.86 2.43 N/A BV3BV*R-1501
2" 10.89 4.25 5.73 2.87 N/A BV3BV*R-2001
2½" 11.34 4.25 6.93 3.47 N/A BV3BV*R-2501
3" 11.34 4.25 7.08 3.54 N/A BV3BV*R-3001 V
A wide variety of options are available: modulating, extra switches, transmitters, potentiometer, etc.
Contact Dixon Sanitary at 800.789.1718 or visit dixonvalve.com for details.
Caution !
Even though there are torque safety factors built into our automated ball valve packages, actual service conditions
must also be considered when selecting the proper product for the appropriate application.
For example: Severe service conditions such as dirty water, dirty air, all slurries, raw sewage water, oils, and other
viscous fuids can have a dramatic affect in raising the torque requirements of ball valves as much as 75% and therefore larger actuators
may be required. Please consult the factory when dealing with these types of applications.